Impacto da medição de sinais de tensão em métodos de localização de curtos-circuitos baseados no domínio do tempo

dc.contributor.advisorReis, Raphael Leite de Andrade
dc.contributor.advisorLatteshttp://lattes.cnpq.br/1139577841043865
dc.contributor.authorSilveira, Mirella Ilka Pereira da
dc.contributor.authorLatteshttp://lattes.cnpq.br/0341519550011359
dc.date.accessioned2020-03-26T02:15:25Z
dc.date.available2020-03-26T02:15:25Z
dc.date.issued2019-12-12
dc.degree.departamentUnidade Acadêmica do Cabo de Santo Agostinho
dc.degree.graduationEngenharia Elétrica
dc.degree.grantorUniversidade Federal Rural de Pernambuco
dc.degree.levelGraduacao
dc.degree.localCabo de Santo Agostinho, PE
dc.description.abstractNeste trabalho, avaliações acerca do impacto da utilização de medições de sinais de tensão no desempenho de métodos de localização de curtos-circuitos em linhas de transmissão (LT) baseados no domínio do tempo são realizadas. Para tanto, algoritmos de localização de faltas considerando medições de um e dois terminais da LT foram implementados no software Matlab®, sendo os dados de entrada das rotinas fornecidas por meio de medições de tensão e corrente provenientes de um transformador de potencial capacitivo (TPC) e de um transformador de corrente (TC), respectivamente. O desempenho das técnicas de localização de faltas é investigado por meio de várias simulações de curtos-circuitos em um sistema elétrico de potência (SEP) de 230 kV, considerando-se variações nos parâmetros de falta, como a resistência e o ângulo de incidência, além da resposta dinâmica do TPC em algoritmos de um terminal, a qual normalmente não é reportada na literatura. Dos resultados obtidos, constata-se que o algoritmo de dois terminais mostrou-se como mais robusto, uma vez que mais informações do SEP são utilizadas como dados de entrada da rotina, muito embora dependa de um canal de comunicação. No que tange ao algoritmo de um terminal, a resposta dinâmica do TPC pode alterar a polaridade das ondas viajantes detectadas no terminal monitorado, comprometendo, desta forma, a confiabilidade deste tipo de método caso mecanismos para compensar a resposta em frequência do dispositivo de medição não estejam disponíveis.
dc.description.abstractxIn this work, the impact of voltage measuraments on the performance of traveling wave-based fault location functions is evaluated. Basically, one- and two-ended fault location algorithms were implemented in Matlab, being the voltage and current measurements used as data input for the routines taken from a coupling capacitive voltage transformer (CCVT) and a current transformer (CT), respectively. The performance of the fault location techniques is investigated by several short-circuit simulations in a 230 kV electrical power system, considering variations in the fault parameters such as resistance and inception angle. The CCVT dynamic response is also token into account, especially in the one-terminal routine, which is rarely reported in the literature. From the obtained results, it can be seen that the two-terminal algorithm has shown to be more robust, since more information about the power network is used as input data, although it depends on a communication path. Regarding the one-terminal function, the CCVT dynamic response end may change the wave polarities detected at the monitored end, which affects the technique if ways to compensate the CCVT frequency response are not available.
dc.format.extent69 f.
dc.identifier.citationSILVEIRA, Mirella Ilka Pereira da. Impacto da medição de sinais de tensão em métodos de localização de curtos-circuitos baseados no domínio do tempo. 2019. 69 f. Trabalho de conclusão de curso (Graduação em Engenharia Elétrica) - Unidade Acadêmica do Cabo de Santo Agostinho, Universidade Federal Rural de Pernambuco, 2019.
dc.identifier.darkflstrmvhttps://n2t.net/ark:/57462/001300000dhtw
dc.identifier.urihttps://repository.ufrpe.br/handle/123456789/2118
dc.language.isopor
dc.publisher.countryBrasil
dc.rightsopenAccess
dc.rights.licenseatribution - non commercial - no derivs 3.0 Brazil
dc.rights.uricreativecommons.org/licenses/by-nc-sa/4.0/deed.pt_BR
dc.subjectLinhas de transmissão
dc.subjectTransformador de potencial
dc.subjectLinhas elétricas
dc.subjectCircuitos elétricos - Localização
dc.titleImpacto da medição de sinais de tensão em métodos de localização de curtos-circuitos baseados no domínio do tempo
dc.typebachelorThesis

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Imagem de Miniatura
Nome:
tcc_MirellaIlkaPereiradaSilveira.pdf
Tamanho:
1.48 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura Disponível
Nome:
license.txt
Tamanho:
1.87 KB
Formato:
Item-specific license agreed upon to submission
Descrição: